Brand |
Daikin |
Model |
2MXM18AVJU9 |
Warranty |
12 Year limited parts warranty with online registration |
BTU |
18,000 BTU (Up to 24,000 BTU) |
Energy Star Certified |
Yes |
ENERGY STAR ® Certified with Cold Climate Designation |
Yes |
Potential Eligibility for IRA Tax Credit |
Yes |
Power Supply |
-
Phase: 1
-
Hz, V: 60 Hz, 208 - 230 V
-
MCA: 15.6
-
MOP: 20.0
|
COP@5°F |
W/W: 1.8 |
EER2 (Btu/W·h) |
12.0
|
SEER2 |
21.0 |
HSPF2 |
10.0 |
Casing Color |
Ivory White |
Compressor |
-
Type: Hermetically Sealed Swing Type
-
Model: 2Y147BKBX1A
-
Motor Output (W): 1,300 W
|
Refrigerant Oil |
-
Model: FW68DA
-
Charge fl oz (L): 22.0 (0.65)
|
Refrigerant |
-
Type: R-32
-
Charge lbs (kg): 3.3 (1.50)
-
Pre-Charge: Pre-Charged for 98.4 ft of line set length
|
Airflow Rates |
-
Cooling: 2,112 (cfm) / 59.8 (m³/min)
-
Heating: 2,140 (cfm) / 60.6 (m³/min)
|
Fan |
-
Type: Propeller
-
Motor Output: 150 W
-
Running Current (Cooling / Heating): 0.31 A / 0.33 A
-
Power Consumption (Cooling / Heating): 65.4 W / 67.7 W
|
Starting Current |
14 A |
Dimensions (H × W × D) |
29-1/2 × 34-1/4 × 12-5/8 inches (750 × 870 × 320 mm) |
Packaged Dimensions (H × W × D) |
32-1/16 × 40-5/16 × 16 inches (814 × 1,024 × 406 mm) |
Weight (Mass) |
127 lbs (58 kg) |
Gross Weight (Gross Mass) |
135 lbs (61 kg) |
Sound Pressure Level |
-
Cooling: 52 dB(A)
-
Heating: 54 dB(A)
|
Piping Connection (inches) |
-
Liquid: 1/4 x 2
-
Gas: 3/8 x 1, 1/2 x 1
-
Drain: 5/8 inches
|
Heat Insulation |
Both Liquid and Gas Pipes |
No. of Wiring Connections |
3 for Power Supply, 4 for Interunit Wiring (Including Ground Wiring) |
Max. Interunit Piping Length |
- 164 ft (50 mm) (for Total of Each Room)
- 82 ft (25mm) (for One Room)
|
Amount of Additional Charge oz/ft(g/m) |
0.22 (20) (98-3/8 ft (30 m) or more) |
Max. Installation Height Difference |
- 49-1/4 ft (15 mm) (Between Indoor Unit and Outdoor Unit)
- 24-5/8 ft (7.5 mm) (Between Indoor Units)
|
Conditions Based on Cooling |
-
Indoor ; 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB)
-
Outdoor ; 95°FDB (35°CDB) / 75°FWB (24°CWB)
-
Piping length: 25 ft (7.5 m)
|
Conditions Based on Heating |
-
Indoor ; 70°FDB (21°CDB) / 60°FWB (15.6°CWB)
-
Outdoor ; 47°FDB (8.3°CDB) / 43°FWB (6°CWB)
-
Piping length: 25 ft (7.5 m)
|